9. ELECTRICAL DATA

Indoor Unit

Outdoor Unit

Complete Unit

Fan Motor

Fan Motor

Compressor

Performance at

230 - 208 V / 1 phase / 60 Hz

Rating conditions

A

0.38 - 0.37

0.90 - 0.90

8.8 - 9.6

10.1 - 10.9

kW

0.08 - 0.07

0.18 - 0.17

2.02 - 2.00

2.25 - 2.24

Full load conditions

A

0.38 - 0.37

0.90 - 0.90

11.1 - 12.4

12.4 - 13.7

kW

0.08 - 0.07

0.18 - 0.17

2.55 - 2.58

2.81 - 2.32

Starting amperes

A

1 - 1

1 - 1

61 - 55

63 - 57

Electrical characteristics

Indoor model: KS2462R / Outdoor model: C2462R, CL2462R

Rating Conditions

: Indoor Air Temperature

80

°

F DB / 67

°

F WB

Outdoor Air Temperature

95

°

F DB

Full Load Conditions : Indoor Air Temperature

80

°

F DB / 67

°

F WB

Outdoor Air Temperature 115

°

F DB