Specifications, 2) major component specifications (b) outdoor unit – Sanyo CL2462R User Manual

Page 9

Advertising
background image

– 9 –

SM830092

2. SPECIFICATIONS

(2)

Major Component Specifications

(B)

Outdoor Unit

MODEL No.

CL2462R

Source

230 - 208 V / 1 phase / 60 Hz

Controller P.C.B. Ass'y

CR - CL2432 (Microprocessor)

Control circuit fuse

250 V, 3 A

Compressor

Scroll (Hermetic)

Model

ZP23K3E

Source

230 - 208 V / 1 phase / 60 Hz

Nominal output

W

2,400

Compressor oil

cc

1,120

Coil resistance (Ambient temperature 77

°

F)

C – R : 0.885 , C – S : 1.773

Safety device

Internal type

Overload relay models

Operating temperature

Open

°

F

284

±

9

Close

°

F

156

189

Operating ampere (at 77

°

F)

A

Run capacitor

VAC,

µ

F

400 V, 40

µ

F

Crank case heater

V,

W

230 V, 30 W

Refrigerant amount charged at shipment

lbs.

(kg)

R410A : 6.6 (3)

High pressure switch

ACB - 1UB24W

Set pressure

OFF MPa

4.15

ON MPa

3.15

±

0.3

Fan

Propeller

Number...diameter

in.

(mm)

1 ... 18 - 3/32 (460)

Fan speeds

3 (AUTO)

Fan motor

Model

KFC6T - 91D6P

Source

230 - 208 V / 1 phase / 60 Hz

No. of pole ..... rpm (230 V, High)

6 ... 879

Nominal output

W

110

Coil resistance

BRN – WHT : 67.14 , VLT – YEL : 11.42

(Ambient temperature 68

°

F)

WHT – VLT

: 64.85 , YEL – PNK : 10.60

Safety device

Internal

Operating temperature

Open

°

F

248

±

9

Close

°

F

171

±

27

Run capacitor

VAC,

µ

F

440 V, 4

µ

F

Heat exchange

Coil

Aluminum plate fin / Copper tube

Rows ..... Fins per inch

2 ... 14.1

Face area

ft.

2

(m

2

)

8.72 (0.81)

+ 0
– 0.15

DATA SUBJECT TO CHANGE WITHOUT NOTICE

Advertising