Specifications, 2) major component specifications (b) outdoor unit – Sanyo CL2462R User Manual

Page 8

Advertising
background image

– 8 –

SM830092

2. SPECIFICATIONS

(2)

Major Component Specifications

(B)

Outdoor Unit

+ 0
– 0.15

DATA SUBJECT TO CHANGE WITHOUT NOTICE

MODEL No.

C2462R

Source

230 - 208 V / 1 phase / 60 Hz

Compressor

Scroll (Hermetic)

Model

ZP23K3E

Source

230 - 208 V / 1 phase / 60 Hz

Nominal output

W

2,400

Compressor oil

cc

1,120

Coil resistance (Ambient temperature 77

°

F)

C - R : 2.28 , C - S : 1.01

Safety device

Internal type

Overload relay models

Operating temperature

Open

°

F

284

±

9

Close

°

F

Operating ampere (at 77

°

F)

A

Run capacitor

VAC,

µ

F

400 V, 40

µ

F

Refrigerant amount charged at shipment

lbs.

(kg)

R410A : 6.6 (3)

High pressure switch

ACB - 1UB24W

Set pressure

OFF MPa

4.15

ON

MPa

3.15

±

0.3

Fan

Propeller

Number...diameter

in.

(mm)

1 … 18-3/32 (460)

Fan speeds

2 (AUTO)

Fan motor

Model

KFC6T - 91D6P

Source

230 - 208 V / 1 phase / 60 Hz

No. of pole … rpm (230 V, High)

rpm

6 … 879

Nominal output

W

110

Internal

Coil resistance

BRW – WHT

:

67.14

,

VLT – YEL

:

11.42

(Ambient temperature 68

°

F)

WHT – VLT

:

64.85

,

YEL – PNK

:

10.60

Safety device

Operating temperature

Open

°

F

248

±

9

Close

°

F

171

±

27

Run capacitor

VAC,

µ

F

440 V, 4

µ

F

Heat exchanger

Coil

Aluminum plate fin / Copper tube

Rows … Fins per inch

2 … 14.1

Face area

ft.

2

(m

2

)

8.72 (0.81)

156

189

Advertising