8. INSTALLATION INSTRUCTIONS

Outdoor Unit

AVOID:

heat sources, exhaust fans, etc. Fig. 4
damp, humid or uneven locations.

DO:

choose a place as cool as possible.
choose a place that is well ventilated and
outside air temperature does not exceed
maximum 115

°

F constantly.

allow enough room around unit for air intake/
exhaust and possible maintenance. Fig. 5
provide a solid base; about 6 inch above
grond level to reduce humidity and possible
water damage in the unit and decrease
service life. Fig. 6
use lug bolts or equivalent to bolt down unit,
reducing vibration and noise.

CAUTION

If more than 2 outdoor units are installed in the
same location, keep at least 3 meters away from
the neighboring unit to avoid influence of air
discharge.

Air discharge chamber for top discharge

Install the air-discharge chamber in the filed when:

it is difficult to keep a space of minimum 2 ft.
between the air-discharge outlet and the
obstacle.
the air-discharge outlet is facing the sidewalk
and discharged hot air can annoy the
passers-by.
Refer to Fig. 6 and Fig. 7.

Out-
door
unit

Heat source

Hot air

Exhaust fan

0591_C_I

Fig. 4

Fig. 5

Min.
1 inch

Min.
1 inch

Min. 2 ft.

4 in.

0931_C_I

Min.
7 ft.

Ground

Air
dis-
charge

0932_C_I

Obstacle above

Air in

Air in

Air
discharge

Concrete block
4 inch 1 ft. 4 inch
beams or equal

Anchor bolts
(4 pieces)

Min. 6 inch

0934_C_I

Fig. 6

Air discharge

0426_C_I

Fig. 7