Processes and functions – Sanyo CL2462R User Manual

Page 37

Advertising
background image

– 37 –

SM830092

(3) Freeze Prevention

Freeze Prevention keeps the indoor heat exchange coil from freezing. Freezing reduces the
efficiency of the unit, and frost buildup on the coil blocks cool air circulation from the indoor
unit’s fan.

11. PROCESSES AND FUNCTIONS

ON

ON

ON

ON

OFF

OFF

Set speed

More than

10 minutes

6 minutes

T + 4

°

F

Indoor heat exch.
coil temp.

30

°

F

Compressor

Indoor fan

Room temp.

Thermo. OFF

Thermo. ON

Set temp. T

°

F

More than

10 minutes

More than

6 minutes

Set speed

2214_M_S

Fig. 13

Chart Summary and Explanations

When the compressor has been running for 6 minutes or more and the temperature of the
indoor heat exchange coil falls below 30

°

F, the control circuit stops the compressor for at

least 6 minutes. The compressor does not start again until the temperature rises above
46

°

F or 6 minutes has elapsed.

Advertising