PinPoint-E EV-DO

131

20070914

hh=13 : Modbus ASCII

hh=23 : Modbus RTU (Binary)

hh=33 : BSAP

hh=63 : Variable Modbus

hh=73 : Reliable UDP

hh=83 : UDP Multicast

S82=n

Enables UDP auto answer (half‐open) mode. 

n=0 : Normal mode

n=2 : Enable UDP auto answer mode.

S83=n

Set or query UDP auto answer idle time‐out. If no data is sent 
or received before the time‐out occurs, the current UDP session 
will be terminated. While a session is active, packets from 
other IP addresses will be discarded (unless *UALL is set).

n=0 : No idle time‐out (Default). 

n=1 ‐ 255 : Time‐out in seconds. 

*DU=n

The dial command always uses UDP, even when using ATDT.

n=0 : Dial using the means specified (default). 

n=1 : Dial UDP always, even when using ATDT.

Note: When this parameter is set you cannot establish a TCP PAD
connection.

*UALL=n

Accepts UDP packets from any IP address when a UDP 
session is active. If there is no UDP session active, an incoming 
UDP packet will be treated according to the UDP auto answer 
and AIP settings. 

n=0 : No effect (Default). 

n=1 : Accept UDP data from all IP addresses when in a 
UDP session. 

Advertising