Sony Remote Control Panel RCP-D50/D51 User Manual

Page 43

Advertising
background image

43

Menu

2ndary menu Submenu

Control item

Function

RCP Config Date/Time

Date

• Year

Date adjustment of the clock built into the unit

Set

• Month

• Day

Set

Cancel

Time

• Hour

Time adjustment of the clock built into the unit

• Minute

• Second

Set

Cancel

Comm Type

Protocol Type

a)

To set the connection mode
P Type 2: When connected to DXC-D35, DXC-D50, CCU-TX7,

CCU-D50, DSR-300/370/390/500/570

P Type 7: When connected to CCU-TX50

Security

Engineer Mode

To set whether to display “Status”, “Menu Set”, and “Code No.” or
not (With Engineer Mode ON, all operative menu items are
displayed regardless of the Advance Mode setting.)

Status

b)

Advance Mode

To switch between the Normal Setting mode and Advanced Setting
mode of the menu

Screen Md Enable

To set whether switching between 4:3 and 16:9 is enabled or not

Pan/Tilt Enable

To set whether panning/tilting adjustment is enabled or not

Power On Active

To specify the Panel Active and Iris/Master Black Active statuses
when the unit is started up
Full Active: To set the unit to the Panel Active status when started up
IRIS/M.Black: To set the unit to the Iris/Master Black Active

status when started up

Lock: To set the unit to the Panel Lock status when started up
Keep state: To set the unit to the previous state when started up

Panel Active Lock

To set whether to use the Panel Active Lock function with a security
code or not.
Disable: Not to use the Panel Active Lock function
Enable: To use the Panel Active Lock function by specifying a
new security code
Enable (Engineer Code): To use the Panel Active Lock function
with the same security code as that for Engineer Mode

Code Change

To change the security code for Panel Active Lock (displayed only
when a security code for Panel Active Lock has been set)

Menu Set

b)

To select an item to be displayed on the function menu. Select the
number (1-7) using • Cur, and select the item with • Sel: White,
Black, Flare, Gamma/Knee, Detail, Cross Color, Skin Detail, Black
STR, Black Gamma, Knee/DL, Gamma, Matrix, Skin Matrix, White
Clip, TLCS, Auto Iris, CLS/EVS, Auto Knee, Low Key Sat, no jump

Code No.

b)

Code No.

To enable/disable the security code setting for Engineer Mode

Code Change

To change the security code for Engineer Mode (displayed only
when a security code for Engineer Mode has been set)

(cont.)

a) Be sure to power off the camera system and then power it on again after changing the “Protocol Type” setting.
b) The items “Status,” “Menu Set,” and “Code No.” are displayed only in Engineer Mode.

Advertising