2-8

CAST-AU4/B2521E

Wiring diagram of connector for external switch (SAFETY)

Applicable plug

Type : DA-15PF-N (pin connector)

Applicable shell

Type : DA-C4-J10

An external stop button can be inserted between pins-14 and –15, or between

pins-14 and –7.

Be sure to use a shielded cable. The maximum length of a shielded cable is 1.5 m. The

external shield must be connected to pin No. 8.

The external equipment (switch, indicator, box, etc.,) to be used for external operation

must be prepared by users.

NOTE

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

24 V

SA RETURN OUT

SA EMG OUT

Stop RELAY OUT (C)

Stop RELAY OUT (NO)

Stop RELAY OUT (NC)

0 V

FG

SA RETURN IN

SA Stop IN (C)

SA Stop IN (NC)

BAR (C)

BAR (NC)

SA Stop ENABLE

0 V

Barrier switch, door switch, etc.

Connector for external switch (SAFETY)

Safety box

Pin No.

Contents

Max 0.1 A

Connect shield
of the cable

RETURN indicator
Stop indicator

These lines can be freely used by users because
these lines are prepared for independent relay
to be energized at the time of stop.
(Pins-4 and -6 are normally closed.
In a stop, pins-4 and -5 are closed.)