background image

4-8

CAST-AU4/B2521E

Solutions

Start operation from the very beginning

Confirm the sensor cable connection

Correct the controller data from TP of the SRX

Symptoms

“E07” appears on display

Machine movement does

not stop (It moves in the

reverse direction.)

Causes

Returning home failed

Sensor cable is defective

Controller data is abnormal

Fault-Finding Chart of 1)

Fault-Finding Chart of 2)

Fault-Finding Chart of 3)

Fault-Finding Chart of 4)

Symptoms

START button does not function

Causes

START button is defective

Solutions

Replace the START button

Solutions

Replace the START indicator

Replace the START button

Replace the external START button

Causes

START indicator is defective

START button has the short circuit

External START switch has the short circuit

Symptoms

START indicator does not illuminate

START indicator keeps flashing

Symptoms

The simple operation

teaching pendant keeps

displaying “666”

“E01” appears on the

simplified TP.

“E02” appears on the

simplified TP.

The main power cannot

be turned on.

The stop indicator keeps

turning on.

Causes

OFF LINE is selected

Internal PC board is defective

Card is not inserted

The card has no program

The CAST specification setting is set to

NO

The main AC power is not turned on

The POWER switch is broken

The STOP button is kept locked.

(Including the teaching pendant)

The external stop signal is being

connected

Solutions

Connect the SYSRUN

Set the machine system to “ONLINE” from the

TP of the SRX

Exchange the internal PC board

Insert the memory card securely

Insert a memory card in which program is stored

Set the CAST specification setting to “YES” from

the TP of the SRX

Connect the AC main power

Exchange the POWER switch

Release the lock

Release the external emergency stops

Alternatively, short pin-1 and pin-2 of the

external switch connector

Advertising