Management Console Connection

The ECS0016 is pre-configured with a default IP Address: 192.168.0.1
and Subnet Mask: 255.255.255.0 .
Directly connect a PC or workstation to the ECS0016. To configure the
ECS0016 with a browser, the connected PC or workstation should have
an IP address in the same range as the ECS0016 (e.g. 192.168.0.100)


To configure the IP Address of your Linux or Unix PC/workstation simply
run

ipconfig. For Windows PCs (Win9x/Me/2000/XP/ NT):

Click

1.

Start > Settings, then select Control Panel and double-click

Network Connections (for 95/98/Me, double click Network).
Right-click on

2.

Local Area Connection and select Properties.

Select

3.

Internet Protocol (TCP/IP) and click Properties.

Select

4.

Use the following IP address and enter the following details:

IP address: 192.168.0.100 Subnet mask: 255.255.255.0.

If you wish to retain your existing IP settings for this network connection,
click

Advanced and add the above as a secondary IP connection.

Please note: For initial configuration, it is recommended that the
ECS0016 be connected directly to a single PC or workstation. If you
choose to connect your LAN before completing the initial setup steps:

Ensure there are

no other devices on the LAN with an IP Address of

192.168.0.1
Ensure the Console Server and the PC/workstation are on the

same

LAN segment, with no interposed router appliances