102

config.portaccess.total
it means you have 0 rules configured. Your
new rule will be the existing total plus 1. So if the previous command gave
you 0, then you start with rule number 1; if you already have 1 rule your
new rule will be number 2 etc.
If you want to restrict access to serial port 5 to computers from a single
C class network 192.168.5.0, you need to issue the following commands
(assuming you have a previous rule in place):
# /bin/config –-set=config.portaccess.rule2.address=192.168.5.0
# /bin/config –-set=config.portaccess.rule2.netmask=255.255.255.0
# /bin/config –-set=”config.portaccess.rule2.description=foobar.”
# /bin/config –-set=config.portaccess.rule2.port5=on
# /bin/config –-set=config.portaccess.total=2
Please note that this rule becomes live right away.


Event Logging Configuration

Remote Serial Port Log Storage
To setup remote storage of serial port 5 log to a remote Windows share
with the following properties (denoted by bolded text), the following com-
mands must be issued (as denoted by italicized text):
# /bin/config –-set=config.eventlog.server.type=cifs
IP Address: 192.168.0.254
# /bin/config –-set=config.eventlog.server.address=192.168.0.254
Directory: C:\\ECS0016\logs\
# /bin/config –-set=config.eventlog.server.path=/ECS0016/logs
Username: cifs_user
# /bin/config –-set=config.eventlog.server.username=cifs_user
Password: secret
# /bin/config –-set=config.eventlog.server.password=secret
Logging level: 2 (input/output logging as well as user connections &
disconnections)
# /bin/config –-set=config.ports.port5.loglevel=2