Installation, Dip switch setup – Samsung MINI SMART SCC-C7325 User Manual

Page 13

Advertising
background image

English – 13

ENG

Installation

DIP SWITCH SETUP

Before you install the camera, you should set the DIP
switches to confi gure the camera ID, Baud rate, and
communication protocol.

Camera ID Setup

ID number of camera is set using binary number.
The example is shown bellow.

Pin

1

2

3

4

5

6

7

8

ID Value

1

2

4

8

16

32

64 128

ex) ID=5

ex) ID=10

on

off

off

on

on

off

off

on

off

off

off

off

off

off

off

off

The range of ID is 0~255. Factory default of
Camera ID is 1.

If you want to control a certain camera, you must
match the camera ID with Cam ID setting of DVR
or Controller.

Communication Protocol Setup

Select the appropriate Protocol with DIP switch
combination.

Switch State

Protocol

Pin1

Pin2

Pin3

Pin4

OFF

OFF

OFF

OFF

Auto Protocol

ON

OFF

OFF

OFF

Pelco-D

OFF

ON OFF

OFF

Pelco-P

ON

ON OFF

OFF

Samsung

If you set the protocol as Auto Protocol, camera
will automatically recognize the kind of Protocol.

Auto Protocol supports Pelco-D and Samsung Protocol.

If you want to control using DVR or system
keyboard, their protocol must be identical to
camera. Otherwise, you can not control the camera.

If you changed camera protocol by changing DIP S/W,
the change will be effective after you reboot the camera.

Factory default of protocol is “Auto Protocol

Communication Baud rate Setup

Select the appropriate Baud rate with DIP switch
combination.

Switch State

Protocol

Pin5

Pin6

Pin7

OFF

OFF

OFF

2400 BPS

ON

OFF

OFF

4800 BPS

OFF

ON

OFF

9600 BPS

ON

ON

OFF

19200 BPS

OFF

OFF

ON

38400 BPS

Factory default of Baud rate is “9600 BPS”



1

2

3

4

5

6

ON

ON

7

8



1

2

3

4

5

6

ON

ON

7

8

Protocol

Buad Rate

Auto Select

RS-485

Terminate

ID Setting (1~255)

Advertising