14 – 10X MINI SMART DOME CAMERA

Installation

RS-485 Termination Resistor

Pin 8 is used for ON/OFF of RS-485 Termination.
Normally, it must be OFF state. Especially when
you have trouble with long Daisy chain style
connection, turn ON this termination switch of last
camera.

Pin 8 RS-485 Termination Resistor (On/Off)

INSTALLATION USING SURFACE
MOUNT ON THE CEILING

SCC-C6323

① Setup DIP Switch (see previous page).

② Screw surface mount bracket to ceiling with 4

screws.

③ Placing lower body to Surface Mount bracket.

The cable must be properly handled into hole of
bracket or side of lower body.

④ Make sure stopper pin of bracket pin is located

the rightmost side of lower body groove as
shown in the picture. Press the dome and turn
clockwise till the pin is located leftmost side
of groove. Detach protection vinyl from dome
cover.

1

2

3

4

5

6

ON

ON

7

8



G