20 – 10X MINI SMART DOME CAMERA

Installation

Power Connection

Please, check the voltage and current capacity of rated power carefully. Rated power is indicated in the back of
main unit.

Power Mode

Input Voltage Range

Power Consumption

C6323/ C6325

C7325

DC 12V

DC 11V ~ 15V

8 W

12W

AC24V

AC 20V ~ 29V

10W

21W

RS-485 Communication

For PTZ control, connect this line to keyboard and DVR. To control multiple cameras at the same time, RS-485
communication lines of them is connected in parallel as shown below.

Video Connection

Connect with BNC coaxial cable.

Alarm Input Connection

Sensor Input

It is noted that short circuit between GND and

Input pin means alarm activation.

If you want to use Alarm Input, the types of sensor
must be selected in OSD menu. The sensor types
are Normal Open and Normal. If sensor type is
not selected properly, the alarm can be activated
reversely.

Normal Open
(N.O)

Sensor output is turned ON when
sensor is activated

Normal Close
(N.C)

Sensor output is turned OFF when
sensor is activated

Relay Output

There are 4 Alarm Outputs and all of them are Relay
contact type. Therefore, you do not have to care about
polarity, AC/DC, and isolations between channels. Care
must be taken for the power capacity of relay contact
written above.

C

P
F

A

S

R

Keyboard Controller DVR



IN1

IN 2

IN COM

IN T ER N AL

INTERNAL

Internal

Relay Out

Power

Relay Out

Advertising