Caution, Warning, Monitor – Sega INITIAL "D" TYPE TWIN. User Manual

Page 80

Advertising
background image

72

www.seuservice.com

73

www.seuservice.com

Primary side and Secondary side

The monitor's circuit which is divided into the Primary side

and Secondary side, is electrically isolated. Do not touch

the primary side, or do not touch both the primary side

and the secondary side simultaneously. Failing to observe

the instruction can cause electric shock and this is very

dangerous. When making monitor adjustments, use a non-

conductive driver and make adjustment without touching

any part other than the Adjustment V. R. and knob. Also,

be sure not to cause a short-circuit to the Primary side and

Secondary side. If short-circuited, it can cause electric

shock or malfunctioning, which is very dangerous.

High-tension Voltage

Some of the parts inside monitor are subject to high-tension voltage in excess of 20,000 volts and

very dangerous. Therefore, do not touch the monitor interior. Should soldering & paper wastes,

etc. be mixed in the monitor interior, turn the power off so as not to cause malfunctioning or fire

hazard.

Static Electricity

Touching the CRT surface sometimes causes you to slightly feel electricity. This is because the

CRT surfaces are subject to static and will not adversely affect the human body.

Installation and removal

Ensure that the Magnetizer Coil, FBT (Fly-Back Transformer), Anode Lead and Focus Lead are

not positioned close to the sheet metal work's sharp edges, etc. and avoid damaging the insulated

portions so as not to cause electric shock and malfunctioning. (For the name of parts, refer to the

above Figures).

SECONDARY SIDE

(Chassis, CRT)

ANODE LEAD

Approx. 29 kV

MAIN BD

FBT Approx.

29 kV

ANODE CAP

FOCUS LEAD

(black)

Approx. 10 kV

SECONDARY SIDE

(Chassis, sheet metal work, CRT, etc.)

Disconnect or unplug

NECK PCB

Approx.

10 kV

REAR PART

PRIMARY SIDE

Connecting the CRT and PCB

For combining the CRT and PCB, use the specified part No. to maintain the status of adjustments

made at the factory. The anode of the CRT itself will be accumulatively charged as time elapses,

generating high-tension voltage which is very dangerous. The monitor should be used with the

Chassis, CRT and PCB assembled. When repair, etc. is required at the time of malfunctioning, be

sure to send it in an "as is assembled" condition. If these are disassembled, what's charged to said

high tension voltage can be discharged, causing a very hazardous situation. Therefore, under no

circumstances should it be disassembled.

When performing such work as installing and removing the monitor, inserting and disconnecting

the external connectors to and from monitor interior and the monitor, be sure to disconnect the

power connector (plug) before starting the work. Proceeding the work without following this

instruction can cause electric shock or malfunctioning.

Using the monitor by converting it without obtaining a prior permission is not allowed. SEGA

shall not be liable for any malfunctioning and accident caused by said conversion.

15. MONITOR

Before handling the monitors, be sure to read the following explanations and comply with the

caution/warning instructions given below. Note that the caution/warning symbol marks and letters

are used in the instructions.

Indicates that handling the monitors by

disregarding this caution may cause a

potentially hazardous situation, which could

result in personal injury and or material

damage.

Indicates the instruction to disconnect a power

connector or to unplug.

Indicates that handling the monitors

erroneously by disregarding this warning

may cause a potentially hazardous situation,

which could result in death or serious injury.

Indicates that access to a specific part of the

equipment is forbidden.

PRIMARY

SIDE

DEMAGNETIZER

COIL

DEMAGNETIZER COIL

15-1 CAUTIONS AND WARNINGS CONCERNING THE SAFETY FOR HANDLING THE MONITORS

WARNING!

WARNING!

WARNING!

CAUTION!

CAUTION!