5-3. Cooling Capacity

115V Single phase 60 Hz

RATING CAPACITY :

9,100 BTU/h

AIR FLOW RATE:

270 CFM

EVAPORATOR

CONDENSER

ENT.TEMP.°F (°C)

AMBIENT TEMP °F (°C)

WB

DB

75

85

95

105

115

(23.9)

(29.4)

(35.0)

(40.6)

(46.1)

TC

9,220

8,770

8,260

7,690

7,050

CI

0.64

0.7

0.76

0.82

0.9

72(22.2)

SHC

6,720

6,490

6,240

5,960

5,650

59

76(24.4)

SHC

7,580

7,350

7,090

6,820

6,510

(15.0)

80(26.7)

SHC

8,470

8,240

7,990

7,690

7,050

84(28.9)

SHC

9,220

8,770

8,260

7,690

7,050

88(28.9)

SHC

9,220

8,770

8,260

7,690

7,050

TC

9,560

9,140

8,680

8,160

7,600

CI

0.65

0.71

0.77

0.84

0.92

72(22.2)

SHC

5,670

5,470

5,260

5,020

4,780

63

76(24.4)

SHC

6,520

6,330

6,120

5,880

5,630

(17.2)

80(26.7)

SHC

7,420

7,220

7,010

6,780

6,530

84(28.9)

SHC

8,270

8,080

7,870

7,630

7,380

88(28.9)

SHC

9,130

8,930

8,680

8,160

7,600

TC

9,930

9,540

# 9,100

8,620

8,090

CI

0.65

0.71

0.78

0.85

0.94

72(22.2)

SHC

4,610

4,450

4,260

4,060

3,850

67

76(24.4)

SHC

5,470

5,300

5,120

4,920

4,700

(19.4)

80(26.7)

SHC

6,360

6,200

6,010

5,810

5,600

84(28.9)

SHC

7,220

7,050

6,870

6,670

6,450

88(28.9)

SHC

8,080

7,910

7,720

7,520

7,310

TC

10,460

10,090

9,700

9,270

8,800

CI

0.66

0.72

0.79

0.87

0.96

72(22.2)

SHC

3,560

3,420

3,270

3,100

2,930

71

76(24.4)

SHC

4,420

4,270

4,120

3,960

3,790

(21.7)

80(26.7)

SHC

5,310

5,170

5,020

4,860

4,680

84(28.9)

SHC

6,170

6,030

5,880

5,710

5,540

88(28.9)

SHC

7,030

6,880

6,730

6,570

6,390

TC

10,670

10,320

9,960

9,540

9,090

CI

0.67

0.73

0.8

0.89

0.99

75

76(24.4)

SHC

3,280

3,160

3,040

2,890

2,740

(23.9)

80(26.7)

SHC

4,180

4,060

3,930

3,790

3,640

84(28.9)

SHC

5,030

4,910

4,790

4,640

4,490

88(28.9)

SHC

5,890

5,770

5,640

5,500

5,350

TC :Total Cooling Capacity (BTU/h)
SHC:Sensible Heat Capacity (BTU/h)
CI :Compressor Input (kW

Rating conditions are

:Outdoor Ambient Temp.95°FDB
:Indoor Unit Entering Air Temp.80°FDB/67°FWB