2-3. only outdoor unit does not run, 2-4. only indoor unit does not run – Sanyo CH1852 User Manual

Page 62

Advertising
background image

58

9-2-3. Only outdoor unit does not run.

A. Check setting temperature.

B. Check PCB Ass'y in either indoor or outdoor unit.

9-2-4. Only indoor unit does not run.

• Indoor PCB Ass'y is defective.

• Indoor PCB Ass'y is defective.

• Check voltage between terminals

No. 3(+) and No. 4 at terminal plate.
(DC 24V)

No voltage appears.

• Outdoor PCB Ass'y is defective.

OK

OK

NO

Is room temperature too low ?

Try to lower setting temperature by
temperature setting button ( button).

Outdoor unit still does
not run.

Remote control unit is defective.

• Try to run using another remote

control unit.

COOL

OK

NO

Is room temperature too high ?

Try to raise setting temperature by
temperature setting button ( button).

Outdoor unit still does
not run.

• Try to run using another remote

control unit.

HEAT

Remote control unit is defective.

000-111

SM

(18-68)

00.3.17

11:49

AM

y [ W 58

Advertising