26

Indoor Unit

KHS1251

Outdoor Unit

CH1251

115 V Single phase 60 Hz

y

RATING CAPACITY :

11,700 BTU/h

AIR FLOW RATE:

330 CFM

EVAPORATOR

CONDENSER

ENT.TEMP.°F (°C)

AMBIENT TEMP °F (°C)

WB

DB

75

85

95

105

115

(23.9)

(29.4)

(35.0)

(40.6)

(46.1)

TC

11,850

11,280

10,620

9,890

9,070

CI

0.89

0.98

1.06

1.15

1.26

72(22.2)

SHC

8,440

8,140

7,800

7,430

7,030

59

76(24.4)

SHC

9,450

9,150

8,810

8,440

8,040

(15.0)

80(26.7)

SHC

10,500

10,200

9,860

9,490

9,070

84(28.9)

SHC

11,510

11,210

10,620

9,890

9,070

88(28.9)

SHC

11,850

11,280

10,620

9,890

9,070

TC

12,300

11,750

11,160

10,490

9,770

CI

0.9

0.99

1.08

1.17

1.29

72(22.2)

SHC

7,180

6,920

6,640

6,320

6,000

63

76(24.4)

SHC

8,190

7,920

7,640

7,330

7,000

(17.2)

80(26.7)

SHC

9,240

8,980

8,700

8,380

8,060

84(28.9)

SHC

10,250

9,980

9,700

9,390

9,060

88(28.9)

SHC

11,260

10,990

10,710

10,400

9,770

TC

12,760

12,260

# 11,700

11,080

10,400

CI

0.91

1

1.09

1.19

1.32

72(22.2)

SHC

5,910

5,690

5,450

5,180

4,900

67

76(24.4)

SHC

6,920

6,700

6,450

6,190

5,900

(19.4)

80(26.7)

SHC

7,970

7,750

7,500

7,240

6,960

84(28.9)

SHC

8,980

8,760

8,510

8,250

7,960

88(28.9)

SHC

9,980

9,760

9,520

9,250

8,970

TC

13,440

12,980

12,470

11,920

11,310

CI

0.92

1.01

1.11

1.22

1.35

72(22.2)

SHC

4,660

4,470

4,270

4,050

3,820

71

76(24.4)

SHC

5,660

5,480

5,280

5,060

4,830

(21.7)

80(26.7)

SHC

6,720

6,530

6,330

6,110

5,880

84(28.9)

SHC

7,720

7,540

7,330

7,120

6,890

88(28.9)

SHC

8,730

8,540

8,340

8,130

7,890

TC

13,710

13,270

12,800

12,260

11,690

CI

0.94

1.02

1.12

1.25

1.38

75

76(24.4)

SHC

4,290

4,130

3,960

3,770

3,580

(23.9)

80(26.7)

SHC

5,340

5,180

5,020

4,830

4,630

84(28.9)

SHC

6,350

6,190

6,020

5,830

5,640

88(28.9)

SHC

7,360

7,200

7,030

6,840

6,640

TC :Total Cooling Capacity (BTU/h)
SHC:Sensible Heat Capacity (BTU/h)
CI :Compressor Input (kW

Rating conditions are

:Outdoor Ambient Temp.95°FDB
:Indoor Unit Entering Air Temp.80°FDB/67°FWB

(kW)

000-111