Sanyo CH1852 User Manual

Page 61

Advertising
background image

57

C. Check remote control unit.

D. Check fuse on the indoor PCB Ass'y.

E. Check TIMER on the remote control unit.

• Timer is turned ON. Check to see

if is displayed on remote
control.

YES

Cancel the timer mode.

ON

OK

OK

• Check fuse on indoor PCB Ass'y

for continuity. (F)

• Check operation lamp to see

if light is ON.

Light is OFF

• Measure resistance of primary and

secondary winding of transformer.
(TR)

Indoor PCB Ass'y or switch Ass'y is
defective.

OK

OK

• Measure resistance of indoor and/or

fan motor winding.

(FM)

• Measure resistance of compressor

motor winding. (CM)

OK

• Measure coil resistance of power

relay.

(PR)

Replace the fuse.

If fuse has been blown,

OK

• Try to run with another remote

control unit.

First remote control unit is defective.

• Check for residue buildup on

transmitter of remote control unit.

• Check for residue buildup on remote

control receiver on front of indoor
unit.

Clean transmitter.

Clean receiver.

000-111

SM

(18-68)

00.3.17

11:49

AM

y [ W 57

Advertising