9. TROUBLESHOOTING

9-1. Check before and after troubleshooting

9-1-1. Check power supply wiring.

Check that power supply wires are correctly connected to terminals No. 7 (L1) and No. 8 (L2) on the terminal

plate in the outdoor unit.

9-1-2. Check inter-unit wiring.

Check that inter-unit wiring is correctly connected to the indoor unit from the outdoor unit.

9-1-3. Check power supply.

Check that voltage is in specified range (±10% of the rating).

Check that power is being supplied.

9-1-4. Check lead wires and connectors in indoor and outdoor units.

Check that coating of lead wires is not damaged.

Check that lead wires and connectors are firmly connected.

Check that wiring is correct.

1
2

4
5
6

8

1
2

3

4
5
6

Indoor

unit

Outdoor

unit

Inter–unit
power wiring

Inter–unit
control wiring

7

Power supply :
Single- phase, 60Hz
115V.....CH0951,CH1251
230/208V............CH1852

3

G

Ground

G

Ground

G

L1

L2

WARNING

Hazardous voltage can cause ELECTRIC SHOCK or

DEATH. Disconnect power or turn off circuit breaker

before you start checking or servicing.