Electrical data, 1. electrical characteristics – Sanyo CH1852 User Manual

Page 34

Advertising
background image

30

6. ELECTRICAL DATA

6-1. Electrical Characteristics

COOLING

Indoor Unit

Outdoor Unit

Complete Unit

Fan Motor

Fan Motor

Compressor

Performance at

115V Single phase 60Hz

Rating Conditions

Running Amps.

A

0.40

0.70

7.4

8.5

Power Input

kW

0.034

0.081

0.775

0.89

Full Load Conditions Running Amps.

A

0.40

0.70

9.1

10.2

Power Input

kW

0.034

0.081

0.985

1.10

Rating Conditions

: Indoor Air Temperature 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
Outdoor Air Temperature 95°F (35°C) D.B.

Full Load Conditions : Indoor Air Temperature 95°F (35°C) D.B. / 70°F (21.2°C) W.B.

Outdoor Air Temperature 115°F (46.1°C) D.B.

HEATING

Indoor Unit

Outdoor Unit

Complete Unit

Fan Motor

Fan Motor

Compressor

Performance at

115V Single phase 60Hz

Rating Conditions

Running Amps.

A

0.40

0.70

7.3

8.4

Power Input

kW

0.034

0.081

0.775

0.89

Full Load Conditions Running Amps.

A

0.40

0.70

8.6

9.7

Power Input

kW

0.034

0.081

0.935

1.05

Rating Conditions

: Indoor Air Temperature 70°F (21.1°C) D.B.
Outdoor Air Temperature 47°F (8.3°C) D.B. / 43°F (6.1°C) W.B.

Full Load Conditions : Indoor Air Temperature 80°F (26.7°C) D.B.

Outdoor Air Temperature 75°F (23.9°C) D.B. / 65°F (18.3°C) W.B.

Indoor Unit

KHS0951

Outdoor Unit

CH0951

000-111

SM

(18-68)

00.3.17

11:49

AM

y [ W 30