Initialization (Reset)/Functional Restriction Setting

In the FUNCTION 1 screen, you can return contrast, image quality, and other settings to their factory-
preset values, specify whether LEDs lights, and enable control via RS-232C (see page 38) among other
functions.

1.

After pressing

SIZE

for about 5 seconds, press

,

,

, and

in that order.

The FUNCTION 1 screen will appear.

2.

Select and set the items you want.

ALL RESET

ADJUSTMENT LOCK

OSD DISPLAY

LED

RS-232C

LOCKED

ON

ON

LOCKED

ALL RESET

UNLOCKED

OFF

OFF

UNLOCKED

FUNCTION 1

3.

Press

MENU

to return to the normal screen.

[ALL RESET]

Function

Returns all settings to their factory preset values. After initialization (reset),
turn the main power switch off and then back on.

[ADJUSTMENT LOCK]

Function

Specifies whether to lock settings such as ADJUSTMENT and WHITE BALANCE.
While locked, the remote control unit cannot perform operations other than turning
power on/off (POWER button) and displaying the FUNCTION 1 screen.

Default

UNLOCKED

LOCKED

Locks the setting.

UNLOCKED

Unlocks the setting.

[OSD DISPLAY]

Function

Hides/shows menus. The FUNCTION 1 screen cannot be hidden.

Default

ON

ON

Displays the menus.

OFF

Hides the menus.

[LED]

Function

Specifies whether to light LEDs.

Default

ON

ON

Lights LEDs.

OFF

Does not light LEDs.

[RS-232C]

Function

Specifies whether to allow control (see page 38) via RS-232C.

Default

UNLOCKED

LOCKED

Disables control via RS232C.

UNLOCKED

Enables control via RS-232C.