Pc operation, Continued), Communication procedure – Sharp PN-455 User Manual

Page 40: Basic operation, Response code format, Command format

Advertising
background image

40

E

PC Operation

(Continued)

Example: VOLM0030

POWR

1 (“

” indicates a space.)

* Be sure to input 4 characters for the parameter. Pad with spaces if necessary.
✕ VOLM30

VOLM

30

(“

” indicates a space. “

” is the carriage return code (0D

H

, 0AH or 0D

H

).)

If a command has “R” listed for “DIRECTION” in the “RS-232C Command table” on page 52, the current
value can be returned by using “?” as the parameter.

Example: 1. If an ID number has not been set:

VOLM????

← From PC to monitor (Current volume setting: ?)

30

← From monitor to PC (Current volume setting: 30)

2. If an ID number has been assigned (For example, ID number = 001)

VOLM

?

← From PC to monitor (“

” indicates a space.)

30

001

← From monitor to PC (“

” indicates a space.)

<Response code format>

When a command has been executed correctly

This is returned when execution of the command
is finished.

When a command has not been executed correctly*

* This is returned when there is no such com-

mand, or when the command cannot be used in
the current state of the monitor (i.e. video auto-
adjustment with video display).

* If there is a bad connection between the PC

and monitor, or if communication has not been
established, nothing is returned (not even
ERR).

If execution of the command is taking some time

If a command takes some time to execute, WAIT
may be returned as the return value. Wait for a
moment, and OK or ERR will be returned. New
commands cannot be received during this time,
even if they are sent.

If RS-232C is locked

If RS-232C control has been locked with the
operation lock (see page 29), LOCKED is re-
turned as the returned value.

Communication procedure

Basic operation

<Command format>

When a command is sent from the PC to the monitor, the monitor operates according to the received
command, and sends a response message to the PC.

C1

C2

C3

C4

P1

P2

P3

P4

Carriage return code

Command field

(4 prescribed

alphanumerical

characters)

Parameter field

(4 character string

comprised of:

0-9, +, -, space, ?)

O

K

Carriage return code

(0D

H

, 0A

H

)

R

R

E

Carriage return code

(0D

H

, 0A

H

)

I

W

T

A

Carriage return code

(0D

H

, 0A

H

)

E

C

D

K

O

L

Carriage return code (0D

H

, 0A

H

)

Advertising