B-5

The modifier character is the sum of the applicable option values based on

Table B-3

.

Table B-3. Modifier Characters

Code Type

Option Value

Option

Code 39

0

No check character or Full ASCII processing.

1

Reader has checked one check character.

3

Reader has checked and stripped check character.

4

Reader has performed Full ASCII character conversion.

5

Reader has performed Full ASCII character conversion and checked one check character.

7

Reader has performed Full ASCII character conversion and checked and stripped check character.

Example: A Full ASCII bar code with check character W, A+I+MI+DW, is transmitted as ]A7AIMID where 7 = (3+4).

Trioptic Code 39

0

No option specified at this time. Always transmit 0.

Example: A Trioptic bar code 412356 is transmitted as ]X0412356

Code 128

0

Standard data packet, no Function code 1 in first symbol position.

1

Function code 1 in first symbol character position.

2

Function code 1 in second symbol character position.

Example: A Code (EAN) 128 bar code with Function 1 character

FNC1

in the first position, AIMID is transmitted as

]

C1AIMID

I 2 of 5

0

No check digit processing.

1

Reader has validated check digit.

3

Reader has validated and stripped check digit.

Example: An I 2 of 5 bar code without check digit, 4123, is transmitted as ]I04123

Codabar

0

No check digit processing.

1

Reader has checked check digit.

3

Reader has stripped check digit before transmission.

Example: A Codabar bar code without check digit, 4123, is transmitted as ]F04123

Code 93

0

No options specified at this time. Always transmit 0.

Example: A Code 93 bar code 012345678905 is transmitted as ]G0012345678905

MSI

0

Check digits are sent.

1

No check digit is sent.

Example: An MSI bar code 4123, with a single check digit checked, is transmitted as ]M14123

D 2 of 5

0

No options specified at this time. Always transmit 0.

Example: A D 2 of 5 bar code 4123, is transmitted as ]S04123

UPC/EAN

0

Standard packet in full EAN country code format, which is 13 digits for UPC-A and UPC-E (not including
supplemental data).

1

Two-digit supplement data only.

2

Five-digit supplement data only.

4

EAN-8 data packet.

Example: A UPC-A bar code 012345678905 is transmitted as ]E00012345678905