Indicators and projector condition, Projector condition, Indicators – Sanyo PLC WTC500L User Manual

Page 77: Appendix

Advertising
background image

77

Indicators and Projector Condition

Check the indicators for the projector condition.

The projector is operating normally .

• • • on

• • • off

• • • blinking at the normal rate

(approx. 1 second ON,
1 second OFF)

• • • blinking slow

(approx. 2 seconds ON,
2 seconds OFF)

• • • blinking fast

(approx. 0.5 seconds ON,
0.5 seconds OFF)

Indicators

Projector Condition

POWER

green / red

WARNING

TEMP.

red

WARNING

FILTER

orange

SHUTTER

blue

LAMP 1/2

REP.

yellow

The projector is off. (The AC power cord is unplugged.)

The projector is in stand-by mode. Press the ON/STAND-

BY button to turn on the projector.

The projector is operating normally.

(The Shutter is open)

The projector is operating normally.

(The Shutter is closed)

The projector is preparing for stand-by or the projection

lamp is being cooled down. The projector cannot be

turned on until cooling is completed and the POWER

indicator lights red.

The projection lamp is being cooled down in the Power

management mode.

The projector is in the Power management mode.

The projection lamp is being cooled down in the Shutter

management mode.

The projector is in the Shutter management mode. Press

the ON/STAND-BY button to turn on the projector.

The filter is scrolled using the Filter control function in the

setting menu. When the filter is being scrolled, the Filter

replacement icon and “ Please wait...” message (Fig. 1)

appear on the screen.

Fig .1 Filter replacement icon and “Please wait...”

• • • Differs according to conditions.

red

green

green

red

red

green

red

green

Appendix