Appendix a product specifications, Im-24-hp a-1 – Sierra INNOVA-MASS 241-VTP User Manual

Page 66

Advertising
background image

Series 24-HP Instruction Manual

Appendix A Specifications

IM-24-HP

A-1

Appendix A Product Specifications

Accuracy

Process
Variables

240 Series In-Line Meters

241 Series Insertion Meters

(1)

Liquids

Gas & Steam

Liquids

Gas &

Steam

Mass Flow
Rate

±1% of rate

over a 30:1

range

(3)

±1.5% of

rate

(2)

over a

30:1 range

(3)

±1.5% of rate

over a 30:1

range

(3)

±2% of

rate

(2)

over a

30:1 range

(3)

Volumetric
Flow Rate

±0.7% of

rate over a

30:1

range

(3)

±1% of rate

over a 30:1

range

(3)

±1.2% of rate

over a 30:1

range

(3)

±1.5% of

rate over a

30:1 range

(3)

Temperature

± 2° F

(± 1° C)

± 2° F

(± 1° C)

± 2° F

(± 1° C)

± 2° F

(± 1° C)

Pressure 0.4%

of

transducer

full scale

0.4% of

transducer

full scale

0.4% of

transducer full

scale

0.4% of

transducer

full scale

Density 0.3%

of

reading

0.5% of

reading

(2)

0.3% of
reading

0.5% of

reading

(2)

Notes:

(1) Accuracies stated are for the total mass flow through the pipe.
(2) Over 50 to 100% of the pressure transducer’s full scale.
(3) Nominal rangeability is stated. Precise rangeability depends on fluid and pipe size.


Repeatability

Mass Flow Rate: 0.2% of rate.

Volumetric Flow Rate: 0.1% of rate.

Temperature: ± 0.2° F (± 0.1° C).

Pressure: 0.05% of full scale.

Density: 0.1% of reading.


Stability Over 12 Months

Mass Flow Rate: 0.2% of rate maximum.

Volumetric Flow Rate: Negligible error.

Temperature: ± 0.1° F (± 0.5° C) maximum.

Pressure: 0.1% of full scale maximum.

Density: 0.1% of reading maximum.


Response Time

Adjustable from 1 to 100 seconds.


Material Capability

Series 240 In-Line Flow Meter:

Any gas, liquid or steam compatible with 316L stainless steel, C276

hastelloy or A105 carbon steel. Not recommended for multi-phase flu-
ids.


Series 241 Insertion Flow Meter:

Any gas, liquid or steam compatible with 316L stainless steel. Not

recommended for multi-phase fluids.


Flow Rates

Typical mass flow ranges are given in the following table. Precise

flow depends on the fluid and pipe size. 241 insertion meters are
applicable to pipe sizes from 2 inch and above. Consult factory for
sizing program.

Water Minimum and Maximum Flow Rates

½-inch

¾-inch

1-inch

1.5-inch

2-inch 3-inch 4-inch 6-inch 8-inch

gpm 1

22

1.3

40

2.2

67

5.5

166

9.2

276

21

618

36

1076

81

2437

142

4270

m

3

/hr .23

5

.3

9.1

0.5

15

1.3

38

2.1

63

4.7

140

8.1

244

18

554

32

970

Advertising
This manual is related to the following products: