Flex-MuxOneNAND4G(KFM4GH6Q4M-DEBx)

- 66 -

FLASH MEMORY

Flex-MuxOneNAND8G(KFN8GH6Q4M-DEBx)

Flex-MuxOneNAND16G(KFKAGH6Q4M-DEBx)

3.6.1 Superload Operation

See Timing Diagrams 6.10

The Superload operation is used to read multiple pages. During Superload operation, up to 4bit errors are corrected.
Once the first data is loaded, an interrupt status returns to ready. The data in DataRAM should be read after next Superload command is
issued. Data is being loaded from NAND to page buffer until whole data in DataRAM is read. The read from the DataRAM can be only syn-
chronous read mode. The status information related to load operation can be checked by the host if required. When host accesses DataRAM,
the address of DataRAM must be a multiple of 4.
Superload operation must be utilized within a same area partitioned as SLC or MLC.

Superload Operation Flow Chart Diagram

NOTE :
1) FSA must be 00 and BSC must be 000 always for Superload operation.
2) BSA must be 1000.
3) In case of Superload operation, the number of sectors to be loaded is 8 sectors.
4) ‘Write 0 to interrupt register’ step may be ignored when using INT auto mode. Refer to chapter 2.8.18
5) For the first load, hosts must issue ‘Load(0000h)’ command.
6) In case of Superload operation, only synchronous read mode is valid.

Host should read data out until end of DataRAM(804FH).
After Reading out the last data(Add:804F), Additional clock should not be asserted.

Write ‘DFS, FBA’ of Flash

Add: F100h DQ=DFS*, FBA

Start

Write ‘FPA, FSA’ of Flash

Add: F107h DQ=FPA, FSA

1)

Write Load Command

Add=F220h DQ=0000h

5)

Wait for INT register or PIN

low to high transition

Add: F241h DQ[15]=INT

Host reads data from

DataRAM 0,1

6)

Wait for INT register or PIN

high to low transition

Add: F241h DQ[15]=INT

Superload Completed

NO

Finished to load

final page?

YES

Select DataRAM for DDP

Add: F101h DQ=DBS*

* DBS, DFS is for DDP

Write 0 to INT register or PIN

4)

Add: F241h DQ=0000h

Write ‘DFS, FBA’ of Flash

Add: F100h DQ=FBA

Write ‘FPA, FSA’ of Flash

Add: F107h DQ=FPA, FSA

Write Superload Command

Add=F220h DQ=0003h

Write 0 to INT register or PIN

4)

Add: F241h DQ=0000h

Host reads data from

DataRAM 0,1

5)

Write ‘BSA

2)

, BSC’ of DataRAM

3)

Add: F200h DQ=0800h

Write System Configuration

Add: F221h DQ=ECC

Register

Read ECC Status Register1

Add: FF00h DQ=ER1[12:8], ER0[4:0]

Read ECC Status Register2

Add: FF01h DQ=ER3[12:8], ER2[4:0]

Read ECC Status Register3

Add: FF02h DQ=ER5[12:8], ER4[4:0]

Read ECC Status Register4

Add: FF03h DQ=ER7[12:8], ER6[4:0]

Read ECC Status Register1

Add: FF00h DQ=ER1[12:8], ER0[4:0]

Read ECC Status Register2

Add: FF01h DQ=ER3[12:8], ER2[4:0]

Read ECC Status Register3

Add: FF02h DQ=ER5[12:8], ER4[4:0]

Read ECC Status Register4

Add: FF03h DQ=ER7[12:8], ER6[4:0]