Operation

1. Connect a RS-232C serial cross cable to SERVICE PORT on the

projector and serial port on the PC.

2. Launch a communication software provided with PC and setup the

communication condition as follows:

3. Type the command for controlling the projector and then enter the

“Enter” key.

Example
When you want to change the input to Computer 2, Type ‘C’ ‘0’ ‘6’

‘Enter’.

Serial Control Interface

This projector provides a function to control and monitor the

projector’s operations by using the RS-232C serial port.

Baud rate

: 9600 / 19200 bps

Parity check:

: none

Stop bit

: 1

Flow control

: none

Data bit

: 8

• The default of the baud rate is set to 9600 bps. If an error occurs in the com-

munication, change the serial port and the communication speed (baud

rate).

• Enter with ASCII 64-byte capital characters and one-byte characters.