Appendix a — wiring requirements, Appendix a—wiring requirements – Spirit Communications System ConnecT/R User Manual

Page 29

Advertising
background image

Appendix A — Wiring Requirements

25

Note the following cabling requirements before
connecting the equipment. If these limits (which
are the same ones that apply to our current
SPIRIT System) are exceeded, the ConnecT/R
may not work properly.

The total wiring length from the controller to
the SPIRIT Telephone cannot exceed a total

of 1000 feet of 24-gauge DIW (twisted-pair

copper) wire or 22-gauge D station wire,
plus 25 feet of 4-wire line cord.

The total wire length from the controller to
the telephone device cannot exceed a total of
1000 feet of 24-gauge DIW (twisted-pair
copper) wire or 22-gauge D station wire,
plus 25 feet of 4-wire line cord.

If the ConnecT/R is installed outside the
building where the controller is located, or
away from the building where the attached
SPIRIT Telephone is located (using exposed
wiring), In-Range/ Out-of-Building protec-
tors (IROB TII Model 371 or ITW Model

SP69073, AT&T order number 31304) must
be installed by a qualified technician.

Contact your AT&T representative for
additional information.

If the telephone device will be in a building
other than where the ConnecT/R is located,

a Block Protector must be installed by a
qualified technician (one Block Protector for
each "remote" telephone device). Order an
AT&T Model 4C1S (comcode 104386545).

In addition, you will need a Building
Entrance Protector, which can house up to

six 4C1S Block Protectors. Order Model

110ANA1-06 (comcode 105736482). Contact
your AT&T representative for additional
information.