Security Systems 808 User Manual

Page 18

Advertising
background image

18 of 22

496336 Issue 1

8.

Press Enter.

The display shows:

LOADING DEFAULTS

Followed by:

00:PROG SYSTEM

The end station now has the full set of Scantronic factory defaults and
needs reprogramming.

NOTES:

1) The Bell output will be energised. If a SAB triggers at this point then check
Menu 51.
2) If you remove power during programming, and you have not created a valid
configuration, then the system will force you to enter programming mode when
you reapply power. To make sure you can re-enter programming mode
successfully the system loads the default Installer Code.

Factory Defaults

When delivered from the factory, the 808 is preprogrammed with the follow-
ing default settings:

System Users

UO1:

Access Code 1234, System Full Use, Zone omit Not
Permitted, Log Access = Permitted, Change Zone names
= Permitted, Change Data and Time = Permitted, Reset
= Permitted

User 02-08: Not Used (Duress=Disabled)
User 00:

Access Code = 7890

Installer programming

Menu 10: Account Name

Menu 11:

Edit Name = No Name

Menu 20: Zone Type

Menu 21:

Zone circuit type = CC

Menu 30: Program zones

Menu 31:

Zone Names = ZO1: Zone 01 (all other zones to Zone
[nnn])

Menu 32:

Zone Types = All zones Not Used (NU)

Menu 40: Program multiflex

Menu 41:

Level Allocation = Level A,B,C,D = None

Menu 42:

Level Exit Mode = All Levels = Timed and terminate (Exit
Time = 10 Seconds)

Menu 43:

Level Entry Time = All Levels 20 Seconds

Menu 44:

Level Flexi-Zones = Not Set Up = NU

Menu 45:

Level Alarm response = All Levels = Full Alarm

Menu 46:

Level Re-Arms response = All Levels = Never

Menu 47:

Keypad allocation = None

Factory Defaults

808