Wiring detector zones, Wiring fsl zones, Figure 3. wiring the 927 keypad – Security Systems 808 User Manual

Page 7

Advertising
background image

496336 Issue 1

7 of 22

I/P

SND

SIG

SRQ +VE

0V

Prog

Test

1
2

Vol

Display

Rear of keypad pcb

Tamper

N/O Exit
Terminate
Button or
N/C Lock Set
Switch

End Station
Connections

0V

SIG

+V

SRQ

Extension Piezo
12VDC
E.E. Sounder
25mA Max.

+

-

To other
keypad(s)

FEZ

To detector

Figure 3. Wiring the 927 Keypad

Important: Please do not connect other devices (for example SAB, speakers and so

on) in the same cable as the remote keypad wiring.

Wiring Detector Zones

The 808 main connector has terminals for eight detector zones. Zones can
be wired as either two wire Fully Supervised Loop (FSL) or four wire Closed
Circuit (CC). However, all eight zones must be of the same circuit type. The
factory default is for CC zones. Use Menu 21 to change between FSL or CC.

Wiring FSL zones

Each FSL zone uses a two wire closed loop, with two resistors of different
values to differentiate between a ‘Circuit’ and ‘Tamper’ signals. A 2K2 (2.2
kohms) resistor is fitted in series at the end of the wired loop (EOL-End-Of-
Line) and a 4K7 (4.7 kohms) resistor fitted across the alarm contact. All
tamper devices are connected in ‘Series’ with the return feed to the end
station, see Figure 4.

808

Wiring Detector Zones

Advertising