Wiring, Wiring 927 keypads, Figure 2. 808 main connector – Security Systems 808 User Manual

Page 6

Advertising
background image

6 of 22

496336 Issue 1

Wiring

The 808 main PCB has facilities for connecting:

Four keypads.
Eight 2-wire FSL detector zones or eight 4-wire closed circuit zones.
Siren (Loudspeakers).
Three outputs.

Figure 2 shows the control unit connector.

Zone 8

CCT 8

A/T 8

Zone 7

CCT 7

A/T 7

Tamper return

Siren

12V

Bell (OP1)

OP2

OP3

+ve

-ve

Outputs

12V Aux

0V

+ve

-ve

SRQ

12V

Sig

0V

Keypads

Zone 6

CCT 6

A/T 6

Zone 5

CCT 5

A/T 5

Zone 4

CCT 4

A/T 4

Zone 3

CCT 3

A/T 3

Zone 2

CCT 2

A/T 2

Zone 1

CCT 1

A/T 1

Figure 2. 808 Main Connector

Wiring 927 Keypads

All keypads must be connected to Keypad terminals on the main PCB or
"daisy chained" to other keypads. Figure 3 shows the connections for each
keypad.

808

Advertising