HOW YOUR WATER SOFTENER WORKS

SECTION 2

10

2A.

FACEPLATE TIMER FEATURES

EXTRA RECHARGE

Sometimes, a manually started regeneration (re-

charge) may be desired, or needed. Two examples

are:

- - You have used more water than usual (guests

visiting) and you may run out of soft water before the

next timer started regeneration.

- - You did not refill the softener with salt before it was

gone.

You can start a regeneration right away, or you can

set the timer to regenerate at the next 2:00 AM (or

other preset recharge time). Do the following.

RECHARGE NOW

n

Press the ON/OFF-HOLD

button and hold until RE-

CHARGE, SERV and FILL be-

gin to flash in the display.

Upon reaching fill, the first

cycle of regeneration, the flash-

ing SERV goes off and FILL is on steady. RE-

CHARGE continues to flash. This regeneration

will last for about 2- 1/2 to 2- 3/4 hours. After this

time, you will have soft water again.

*NOTE:

If the CLEAN feature is set to ON, a cleaning

backwash precedes the recharge. CLEAN and Bkwsh

or Rinse flashes in the display, along with the minutes

of the clean cycle remaining.

RECHARGE TONIGHT

n

Press and release (do not hold)

the ON/OFF-HOLD button.

RECHARGE

TONIGHT

flashes in the display, and the

softener begins regeneration at

the next preset recharge time.

Press and release the ON/OFF-HOLD button

once more if you decide to cancel the regenera-

tion, and RECHARGE TONIGHT.

SALT MONITOR SYSTEM

The faceplate timer has a low salt monitor with an

indicator light to remind you to refill the storage tank

with salt. To set this monitor system:

1.

Lift the salt hole cover and level the salt in the

storage tank (press tank light button to light inside

of tank).

2.

The salt level decal, on the brinewell inside the

tank, has numbers from 0 to 8 (see drawing on

page 9 and below). Observe the number the

leveled salt is at or closest to.

3.

Now, press the SALT LEVEL ADJUST button

until black bars display up to the salt level

number. For example, the pictures below show

the salt level at 6.

4.

Finally, set the level you want the low salt

indicator light to come on. Press the SIGNAL

LIGHT ADJUST button until a (T) shows oppo-

site this number. In the example below, the light

will come on when the stored salt drops to level 2.

At level 2, the storage tank is about 1/3 full. This

is the lowest you should allow the stored salt

level to drop to. To turn the salt monitor off,

press the button until OFF shows.

SALT

LEVEL

brinewell

decal

salt

level

bars, salt

level

8

7

6

8
7

6
5
4

3
2

1

SALT

LEVEL

SIGNAL

LEVEL

TANK

LIGHT

SIGNAL

LIGHT

ADJ.

SALT

LEVEL

ADJ.

indicator light

LOW SALT

NOTE:

For accurate salt monitor operation, always use

nugget or pellet water softener salt. See page 9. If

potassium chloride is used, be sure to adjust the

timer to the KCl setting on page 7.

8

7

6

5

4

3

2

1

SALT

LEVEL

SIGNAL

LEVEL

PM

RECHARGE

Serv
Fill

8

7

6

5

4

3

2

1

SALT

LEVEL

SIGNAL

LEVEL

PM

RECHARGE TONIGH