Service tech information, 5a. troubleshooting – Kenmore 625.348670 User Manual

Page 23

Advertising
background image

SERVICE TECH INFORMATION

SECTION 5

23

5A.

TROUBLESHOOTING

should get a reading in the display. If you get a

reading, unhook the in and out plumbing and check

the turbine for binding.

SENSOR

HOUSING

TURBINE

TURBINE

SUPPORT &

SHAFT

VALVE POSITION INDICATORS: Depending on the

valve position, the following indicators show in the

display:

INDICATOR

VALVE POSITION

Serv

service

. . . . . . . . .

Fill

fill

. . . . . . . . . . .

Brine

brining/brine rinse

. . . . . . . . .

Bkwash

backwash

. . . . . .

Rinse

fast rinse

. . . . . . . .

When the valve is rotating from 1 cycle to another,

both indicators flash. For example, if the valve is in

transition between fill and brining, both Fill and

Brine flash. Upon reaching brining position, Fill goes

off and Brine is on steady. The time display shows the

minutes of the cycle remaining.

NOTE: If the faceplate is left in a diagnostic display

(or a flashing display when setting times or

hardness), present time automatically returns if a

button is not pressed within 4 minutes. To return to

the diagnositc display, repeat step 2.

OTHER INFORMATION: While in this diagnostic

screen, the following information is available and may

be beneficial for various reasons. This information is

retained by the computer from the first time electrical

power is applied to the faceplate.

¼ Press

to display the number of days this face

plate has had electrical power applied.

¼ Press

to display the number of regenerations

initiated by this faceplate since the HF code number

was entered.

3.

Press the #1 SELECT button and hold 3 seconds

until¼

This code identifies the softener nominal capacity

size. If the wrong number shows, the softener will

operate on incorrect programming. Do the following

as needed.

HF32 does show — Press the #1 SELECT button to

return the present time display.

To change HF number - Press the

or

button

until HF32 shows. Then, press the #1 SELECT button

and reset the timer¼ page 6.

TIMER (PWA) REPLACEMENT: Be sure the

valve is in service position (observe valve

cycle indicator) when replacing the timer

(PWA).
If, after installing and programming the re-

placement timer (PWA), the valve is not in ser-

vice position, do the following to assure correct

cycle orientation, or timing, between the face-

plate and valve.
Use the MANUAL ADVANCE procedures,

page 24. With the RECHARGE NOW button,

advance through the recharge cycles until the

valve stops in service position, and RE-

CHARGE no longer flashes in the display.
NOTE: The valve motor may automatically

drive through several valve positions while

searching for service. If an error code occurs,

unplug the transformer, then plug in again.

CAM

MOTOR

position

markers

(valve in

service)

. . . HF32 shows.

8

7

6

5

4

3

2

1

SALT

LEVEL

SIGNAL

LEVEL