TROUBLESHOOTING

MANUAL ADVANCE REGENERATION CHECK

This check verifies proper operation of the valve

motor, brine tank fill, brine draw, regeneration flow

rates, and other controller functions. Always make

the initial checks, and the manual initiated diag-

nostics.

NOTES: The faceplate display must show a steady

time (not flashing). If an Error code shows, first press

the #1 SELECT button to enter the diagnostic display.

1.

Press the ON/OFF-HOLD button and hold in for

3 seconds. RECHARGE NOW and FILL begin to

flash (or clean backwash begins, if set) as the

softener enters the fill cycle of regeneration.

When FILL is on steady, remove the brinewell

cover and, using a flashlight, observe fill water

entering the tank.

a.

If water does not enter the tank, look for an ob-

structed nozzle, venturi, fill flow plug, brine tub-

ing, or brine valve riser pipe.

CYCLE FLOW RATES (GALLONS PER MIN.)

FILL (flow to salt storage tank)

0.3 (1.1 liters)

BRINING

.16 (.61 liters)

BRINE RINSE

(flow to drain)

.12 (.45 liters)

BACKWASH

(flow to drain) 1.8 (6.8 liters)

FAST RINSE

1.8 (6.8 liters)

2.

After observing fill, press the ON/OFF-HOLD

button to move the softener into brining. A slow

flow of water to the drain will begin. Verify brine

draw from the brine tank by shining a flashlight

into the brinewell and observing a noticeable

drop in the liquid level.

NOTE: Be sure a salt bridge is not preventing water

with salt contact.

a.

If the softener does not draw brine¼
¼ nozzle and/or venturi dirty or defective.

¼ nozzle and venturi not seated properly on

gasket.

¼ restricted drain (check drain fitting and

hose).

¼ defective nozzle and venturi seal.

¼ other inner valve defect (rotor seal, rotor &

disc, wave washer, etc.).

NOTE: If water system pressure is low, an elevated

drain hose may cause back pressure, stopping brine

draw.

3.

Again press ON/OFF-HOLD to move the soften-

er into backwash. Look for a fast flow of water

from the drain hose.

a.

An obstructed flow indicates a plugged top dis-

tributor, backwash flow plug, or drain hose.

4.

Press ON/OFF-HOLD to move the softener into

fast rinse. Again look for a fast drain flow. Allow

the softener to rinse for a few minutes to flush out

any brine that may remain in the resin tank from

the brining cycle test.

5.

To return the softener to service, press ON/OFF-

HOLD.

BRINE VALVE

FLOAT SETTING

(Distance from top of resin tank, to top of resin bed.)

FREEBOARD

7”-- 11”

10”