Service tech information, 5a. troubleshooting, Wiring schematic – Kenmore 625.348670 User Manual

Page 21: Faceplate

Advertising
background image

SERVICE TECH INFORMATION

SECTION 5

21

5A.

TROUBLESHOOTING

Keep this manual with your water softener. If repairs are needed, the service technician must have the informa-

tion on the following 8 pages. For telephone assistance, call toll free, 1- 800- 426- 9345.

WIRING SCHEMATIC

Motor, 24VAC

24VAC

Transformer

GND

OUT

+5

NC

NO

BACK OF FACEPLATE

TIMER (PWA)

AC INPUT

Turbine

Sensor

Position

Switch

grn

brn

POS / TURBINE

MOTOR

Tank Light

grn

brn

SIGNAL

LIGHT

ADJUST

SELECT

1

ON/OFF

HOLD

RECHARGE TONIGHT

RECHARGE NOW

Genius II Water Softener

Kenmore Water Line

for Customer Assistance

1--800--426--9345

SALT

LEVEL

ADJUST

LOW SALT

TANK

LIGHT

SELECT

2

FACEPLATE

ALWAYS MAKE THESE INITIAL CHECKS FIRST

1.

Does the time display show the correct time of day?

- - If display is blank, check power source to the soft-

ener.

- - If time is flashing, power was off for over 24 hours.

The softener resumes normal operation but regen-

erations occur at the wrong time.

- - If an error code (Example: Err3) shows in the face-

plate display, go to AUTOMATIC ELECTRONIC

DIAGNOSTICS.

2.

Plumbing bypass valve(s) must be in full service

position.

3.

The inlet and outlet pipes must connect to the softener

inlet and outlet respectively.

4.

Is the transformer plugged into a “live”, grounded

wall outlet, and the power cable fastened securely?

5.

The valve drain hose must be free of kinks and sharp

bends, and not elevated over 8 ft. above the floor.

REMOVE THE TOP COVER AND SALT TANK COVER

6.

Is there salt in the storage tank? If you are using

potassium chloride, did you reset the timer in step 5,

page 7.

7.

Is the brine tubing connected? (See water flow

diagrams).

8.

Is the brine valve float set right? (See page 24).

9.

Press the #1 SELECT button 2 times to display the

hardness setting. Be sure it is the correct setting for the

household’s water supply. (Make a hardness test of

the raw water and compare with the hardness setting.

Also test a soft water sample to verify if a problem

exists.) Press the #1 SELECT button twice more to

return to present time in the display.

If you do not find the problem after making initial checks,

do the MANUAL INITIATED ELECTRONIC DIAGNOS-

TICS, and the MANUAL ADVANCE REGENERATION

CHECK.