HOW YOUR WATER SOFTENER WORKS

SECTION 2

12

2A.

FACEPLATE TIMER FEATURES

OTHER FEATURES

TANK LIGHT

To light the inside of the salt

storage tank, press the TANK

LIGHT button on the faceplate.

Press the same button again to

turn the light off, or it will go off

automatically in 4 minutes.

WATER FLOW RATE THROUGH SOFTENER

To view the gallon (or liter) per minute water flow

rate through the softener, if not already displayed,

press the #2 SELECT button. If

soft water is being used, the flow

rate to the closest 1/10 gallon (or

liters) shows. If all faucets and

water using appliances are off,

the display will show 0 flow.

AVERAGE DAILY GALLONS

or LITERS

Press the #2 SELECT button

again to show the average num-

ber of gallons of soft water the household uses each

day. This water usage figure is adjusted daily by the

faceplate timer. To turn this display off, press the #2

SELECT button once more.

RECHARGE TIME REMAINING and VALVE

POSITION INDICATORS

One of the valve position indica-

tors (Serv, Fill, Brine, Bkwsh,

Rinse) is displayed while the

softener is recharging (See

*NOTE on page 10 if the CLEAN

feature is set to ON). RE-

CHARGE flashes in the display

and, beginning with Brine, the minutes of recharge

remaining before return to service appears in place of

the present time. When the valve is moving from one

cycle to another, both position indicators are flash-

ing.

LOW SALT INDICATOR LIGHT

When on, you need to refill the salt storage area with

salt. After refilling, reset the salt monitor to turn the

light off. Refer to Salt Monitor System, page 10.

PROGRAM MEMORY

If electrical power to the softener goes off, the time

display is blank but the faceplate timer keeps the

correct time for about 48 hours. When electrical

power comes on again, you have to reset the present

time only if the display is flashing. The HARDNESS

and RECHARGE TIME never require resetting

unless a change is desired.

Even if the timer is incorrect after a long power

outage, the softener works as it should to keep your

water soft. However, regenerations may occur at the

wrong time of day until you reset the timer to the

correct time of day.

ERROR CODE

An error code could appear in

the faceplate display if a problem

occurs in the softener electronics.

If you see an error code instead

of the present time of day, please

call you local Sears Service De-

partment for service.

8

7

6

5

4

3

2

1

SALT

LEVEL

SIGNAL

LEVEL

PM

TANK

tank light ON

indicator

8

7

6

5

4

3

2

1

SALT

LEVEL

SIGNAL

LEVEL

PM

8

7

6

5

4

3

2

1

SALT

LEVEL

SIGNAL

LEVEL

PM

AVG. DAILY GALLON

FLOW RATE

GPM

8

7

6

5

4

3

2

1

SALT

LEVEL

SIGNAL

LEVEL

Serv

Fill

Brine

MIN

RECHARGE

TIME REMAINING

valve

position

indicators

recharge

time

remaining

Bkwsh

Rinse

8

7

6

5

4

3

2

1

SALT

LEVEL

SIGNAL

LEVEL

Advertising