Other things to know, 4a. dimensions/specifications fig. 12 – Kenmore 625.348670 User Manual

Page 20

Advertising
background image

OTHER THINGS TO KNOW

SECTION 4

20

4A.

DIMENSIONS/SPECIFICATIONS

FIG. 12

BYPASS VALVES

Bypass

Valve

Inlet

Valve

Outlet

Valve

3 -- VALVE

FOR SERVICE

close bypass valve

open inlet & outlet valves

FOR BYPASS

open bypass valve

close inlet & outlet valves

PUSH IN

for bypass

PULL OUT

for service

SINGLE

Bypass valve(s) should always remain in soft

water service position. Position in “bypass”

only if needed for softener repairs.

A

B

C

D

E

F

INCHES

CM

A

Salt Tank Height

40-1/4

102.2

B

Resin Tank Diameter (nominal)

9

22.7

C Resin Tank Height (nominal)

40

101.6

D Inlet-Outlet Height

41-1/2

105.4

E

Overall Height

47

119.4

F

1

Length

19-1/2

49.5

F

2

Width

16-1/2

41.9

Distance between inlet-outlet

center lines

3-7/8

9.8

MODEL NO. 625.348670

TIMER HF CODE HF32

NOTE: Please see the rating decal for water softener operating capacity, salt usage and service flow rate/pres-

sure loss performance specifications. Performance specifications are validated by the Water Quality Associa-

tion (WQA). The rating decal is located on the rim, under the salt hole cover (see page 30).

WATER SUPPLY TO WATER SOFTENER

MINIMUM WATER SYSTEM FLOW (gpm)

3

. . . . . . . . . . . . . . . .

MINIMUM-MAXIMUM WATER PRESSURE (psi)

20-120

. . . . . .

MAXIMUM WATER TEMPERATURE (°F)

120

. . . . . . . . . . . . . . .

MAXIMUM WATER HARDNESS (gpg)

110

. . . . . . . . . . . . . . . . . .

MAXMUM “CLEAR WATER”IRON (ppm)

8

. . . . . . . . . . . . . . . . .

SALT FOR WATER SOFTENER

TYPE OF SALT NEEDED

Nugget/Pellet

. . . . . . . . . . . . . . . . . . . .

ALTERNATE TYPE OF SALT

Pure, evaporated, compacted

. .

water softener salt

STORAGE CAPACITY (pounds)

200

. . . . . . . . . . . . . . . . . . . . . . .

OTHERS

TYPE OF ION EXCHANGE MATERIAL (resin)

High Capacity

AMOUNT OF RESIN (cu.ft.)

1.05

. . . . . . . . . . . . . . . . . . . . . . . . . .

REGENERATION (RECHARGE) CYCLE TIME (min.)

FILL (NaCL setting)

2.7-10.6

. . . . . . . . . . . . . . . . . . . . . . . . . . .

FILL (KCl setting)

3.8-12.6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

BRINING / BR. RINSE

120-135

. . . . . . . . . . . . . . . . . . . . . . . . .

BACKWASH

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FAST RINSE

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TOTAL REGENERATION TIME

139.4---164.4

. . . . . . . . . . . .

gpm = gallons per minute

psi = pounds per square inch

gpg = grains per gallon

ppm = parts per million

Advertising