How your water softener works, 2a. faceplate timer features, Optional adjustable settings – Kenmore 625.348670 User Manual

Page 11: Gallon or liter readings - defaults to gallons, Clean feature minutes - default is 7, Press #1 select button, Press #1 select to return the present time display

Advertising
background image

HOW YOUR WATER SOFTENER WORKS

SECTION 2

11

2A.

FACEPLATE TIMER FEATURES

OPTIONAL ADJUSTABLE SETTINGS

Following is a list of other timer features that are

adjustable, and the default setting for each. The

defaults automatically set when electrical power is

applied to the timer. If you want to change from any

of the default values, scroll through steps 1 - 5 below,

and reset as desired.

1. Press and hold the #1 SELECT button for 3 seconds

until the faceplate display changes. Then, press and

release the #1 SELECT button to display 12 hr.

"

12 or 24 Hour clock - defaults to 12 hr:

At the 12

hr default setting, all time displays are shown in

standard clock time (1 to 12 PM; and 1 to 12 AM). If

military time displays are desired (0100, 0200, etc.),

set to 24 hr by pressing the UP button.

8

7

6

5

4

3

2

1

SALT

LEVEL

SIGNAL

LEVEL

8

7

6

5

4

3

2

1

SALT

LEVEL

SIGNAL

LEVEL

TIME

TIME

AM

PM

2. Press #1 SELECT BUTTON

"

Gallon or Liter readings - defaults to gallons:

Water usage and flow displays are shown in gallons.

If you prefer to have the same displays in liters, press

the UP button until Liter shows.

8

7

6

5

4

3

2

1

SALT

LEVEL

SIGNAL

LEVEL

8

7

6

5

4

3

2

1

SALT

LEVEL

SIGNAL

LEVEL

GALLONS

LITERS

3. Press #1 SELECT BUTTON

"

Maximum Days Between Regenerations -

default is zero days:

The faceplate timer automati-

cally controls regeneration frequency (see page

14). This provides the greatest operating efficiency,

and normally the maximum days feature is not

needed. If you want to be certain a regeneration will

occur within a number of days, use this feature. For

example, if your water supply contains iron and you

want the softener to regenerate at least once every few

days to keep the resin bed clean, set the display as

typically shown below. Setting is available from 1 to

15 days by using the UP and DOWN buttons.

NOTE:

Setting a number in this display may override the

function of the water meter and timer computer (see

page 15). For example, assume the meter/computer

would initiate softener regenerations every 6 or 7

days. If you have max days set to 4, as shown below,

regenerations will occur every 4 days instead of

every 6 or 7.

8

7

6

5

4

3

2

1

SALT

LEVEL

SIGNAL

LEVEL

8

7

6

5

4

3

2

1

SALT

LEVEL

SIGNAL

LEVEL

RECHARGE

DAY

default display

example: set to

4 days maxi-

mum between

regenerations

RECHARGE

DAY

4. Press #1 SELECT BUTTON

"

CLEAN feature minutes - default is 7

minutes

:

If you have set this feature to ON (page 7), the length

of the extra backwash cycle automatically sets to 7

minutes. However, you can adjust this time from 1 to

15 minutes in length. If you have a minimum of iron

or sediments, a 3 or 4 minute clean cycle may be

enough to keep the resin bed clean. If you have a

higher amount of iron or sediments, a setting of over

7 minutes may be needed. To change this cycle time,

use the UP button to increase the time, or the DOWN

button to shorten the time.

8

7

6

5

4

3

2

1

SALT

LEVEL

SIGNAL

LEVEL

8

7

6

5

4

3

2

1

SALT

LEVEL

SIGNAL

LEVEL

CLEAN

TIME

MIN

CLEAN

TIME

MIN

default minutes

example: time set to 3 minutes

5. Press #1 SELECT to return the present time

display.

Advertising