6 malfunction messages, Malfunction messages -9 – Konica Minolta Magicolor 5440 DL User Manual

Page 112

Advertising
background image

Main Unit Field Service

Description of the Control Panel (magicolor 5430 DL /5440 DL)

3-9

III

Ad

just

men

t/Set

ting

3.2.6

Malfunction messages

☞ For details of malfunction messages and troubleshooting procedures, see “IV Trouble-

shooting.”

*: The lower the message in the above list, the higher the priority.

Message

Description

ILLEGAL ERROR
DUPLEX

• A Duplex Option is not installed.
• A 2-sided print cycle has been initiated using a type and size of media not

supported for 2-sided printing.

ERROR
AIDC SENSOR

• The AIDC Sensor is faulty.

FATAL ERROR
CODE:XXXX

• The Engine or Controller is faulty.

ERROR
COMMUNICATION

• A communications error has occurred in the USB or Ethernet interface.

ERROR
ENGINE INTERFACE

• There is a connection fault between the Mechanical Control Board (PWB-A)

and Print Control Board (PWB-P).

ERROR
RAM

• An error has occurred during RAM read/write operations.

ERROR
DIMM

• A fault has occurred in SDRAM DIMM.

ERROR
ROM

• An error has occurred in ROM.

ERROR
CONTROLLER

• A fault has occurred in the controller.

5450_E.book_PDF.book 9 ページ 2005年4月12日 火曜日 午後12時54分