Konica Minolta Magicolor 5440 DL User Manual
Page 76
Advertising
Main Unit Field Service
Other
2-39
II Main
tena
nce
4.
Remove six screws [3] and the
Mechanical Control Board protective
shield [4].
5.
Disconnect all connectors and flat
cables from the Mechanical Control
Board [5].
6.
Remove eight screws [6] and the
Mechanical Control Board [7].
[3]
[4]
4138fs2071c0
[5]
4138fs2072c1
[6]
[7]
4138fs2073c1
5450_E.book_PDF.book 39 ページ 2005年4月12日 火曜日 午後12時54分