17 toner level sensor board (pwb-d), 17 toner level sensor board (pwb-d) -44 – Konica Minolta Magicolor 5440 DL User Manual
Page 81
Other
Main Unit Field Service
2-44
II Main
tena
nce
Precautions for Reinstallation
• When reinstalling High Voltage
Unit/2, make sure that each color
connector is in the correct position,
as shown in the illustration on the
left.
4.4.17
Toner Level Sensor Board (PWB-D)
1.
Open the Front Door.
2.
Remove the Toner Cartridge and Waste Toner Bottle.
3.
Remove the Upper Front Cover and Right Front Cover.
☞ 2-30
4.
Remove the Control Panel.
☞ 2-34
5.
Remove the Exit Tray.
☞ 2-32
6.
Remove the Mechanical Control Board protective shield.
☞ Steps 1 to 4 on p.2-38 “Mechanical Control Board”
7.
Disconnect one connector (PJ13A)
[1] from the Mechanical Control
Board.
White
Yellow
Red
Blue
White
Red
Yellow
Red
Blue
White
4138fs2531e0
[1]
4138fs2532c0
5450_E.book_PDF.book 44 ページ 2005年4月12日 火曜日 午後12時54分