Power supply troubles, 2 control panel indicators do not light, Power supply troubles -27 – Konica Minolta Magicolor 5440 DL User Manual

Page 214: Control panel indicators do not light -27

Advertising
background image

Main Unit Field Service

Power Supply Troubles

4-27

IV

T

roub

lshoo

t

in

g

3.

Power Supply Troubles

3.1

Machine is Not Energized at All (LV Operation Check)

3.2

Control panel indicators do not Light

Relevant Electrical Parts

Power Switch
Mechanical Control Board (PWB-A)

Low Voltage Unit (LV)

Step

Check Item

Location

(Electrical

Component)

Result

Action

1

Is the power source voltage being applied to
CN1LV on LV?

12-L

NO

Check wiring from
power outlet to PG1 to
CN1LV.

2

Are fuses (F1 and F2) on LV conducting?

-

NO

Change LV.

3

Are DC24 V and DC5 V being applied to
CN5V on the Mechanical Control Board?

10-K

∼L

NO

Change LV.

YES

Change PWB-A.

Relevant Electrical Parts

Print Control Board (PWB-P)
Control Panel (PWB-OP)

Low Voltage Unit (LV)

Step

Check Item

Location

(Electrical

Component)

Result

Action

1

Is the power source voltage being applied to
CN1LV on LV?

12-L

NO

Check wiring from
power outlet to PG1 to
CN1LV.

2

Are fuses (F1 and F2) on LV conducting?

-

NO

Change LV.

3

Is CN10P on PWB-P properly connected?

14-B

NO

Reconnect.

4

Is CN20P on PWB-OP properly connected?

11-E

∼F

NO

Reconnect.

YES

Change PWB-OP.
Change PWB-P.

5450_E.book_PDF.book 27 ページ 2005年4月12日 火曜日 午後12時54分