Page 4-2

L-3 ELAC Nautik

CURSOR

GAIN

RANGE

DIM

ESCAPE

ENTER

PRINT

MARKER

ON

OFF

GAIN

: The GAIN keys are used to alter the system gain, otherwise known as

amplification, to achieve a clearer presentation. The system can be operated

with either automatic or manual gain control. See chapter 4.4.1.

RANGE

: The RANGE keys are used to set the depth range of the system.

DIM

: The DIM keys are used to set the display backlighting level to suit the user.

CURSOR

GAIN

RANGE

DIM

ESCAPE

ENTER

ON

OFF

PRINT

MARKER

PRINT

: The PRINT key is used when the user wishes to make a simultaneous hard copy

of the echogram. This is only possible if a printer is connected to the system.

MARKER

: When the MARKER key is pressed, a vertical dotted line appears on the screen

and moves with the presentation from right to left. At the same time all relevant

information is stored in the system's 24 hour memory. This memory stores data

from the previous 24 system operating hours.

SYMBOL

: The key marked with a loudspeaker symbol is used to acknowledge acoustic

depth alarms.