Page 5-9

L-3 ELAC Nautik

The CHANNEL 1 MENU allows the service technician to set the following parameters:

Draft

the transducer installation depth is entered here, i.e. the depth

of the transducer below the waterline, e.g. 5.6 m. This

compensation allows accurate surface to sea bed

measurements..

Trim

the distance between the transducer and the lowest part of the

keel is entered here, e.g. 0.3 m. This compensation allows

accurate keel to sea bed measurements.

Blocking depth this setting is to prevent false digital depth readings caused by

the effects of resonance of non-ELAC transducers. If the water

depth is less than the depth set here, the digital display will show

a „?“ but the analogue depth reading will be displayed correctly.

Frequency

the transducers working frequency is entered here, e.g. 50 kHz.

Location

the position where the transducer is installed is entered here,

e.g. BOW. This parameter can not be altered for single

channel systems.

To alter the Draft setting, press the following keys:

• Call up the CHANNEL 1 SUB MENU as described previously
CURSOR W (1x, to mark the word Draft)
ENTER (1x, to mark the 1st digit)
CURSOR W or V (to alter the metre (1st digit) setting)
ENTER (1x, to confirm selection and jump to 2nd digit)
CURSOR W or V (to alter the 1/10th of a metre (2nd digit) setting)
ENTER (1x, to confirm selection)
ESCAPE (2x, to leave the MENU)

To alter the Trim setting, press the following keys:

• Call up the CHANNEL 1 SUB MENU as described previously
CURSOR W (2x, to mark the word Trim)
ENTER (1x, to mark the 1st digit)
CURSOR W or V (to alter the metre (1st digit) setting)
ENTER (1x, to confirm selection and jump to 2nd digit)
CURSOR W or V (to alter the 1/10th of a metre (2nd digit) setting)
ENTER (1x, to confirm selection)
ESCAPE (2x, to leave the MENU)

To alter the Blocking Depth setting, press the following keys:

Advertising