Input rectifier, Troubleshooting & repair, Procedure – Lincoln Electric POWER WAVE 355/405 SVM159-A User Manual

Page 108

Advertising
background image

PROCEDURE

1. Remove input power to the POWER WAVE

355/405.

2. Using a 5/16” nut driver remove the case

wraparound cover.

3. Perform the Input Filter Capacitor Discharge

Procedure detailed earlier in this section.

4. Locate the input rectifier. See figure F.30.

5. Carefully remove the silicon sealant insulating the

six input rectifier terminals.

6. Remove the six screws from the terminals using a

flathead screwdriver. Carefully note the position of
all leads and their positions upon removal. See
Figure F.31.

7. Using a 3/16”in. allen wrench remove the two

mounting screws and washers from the input
bridge. See Figure F.31.

8. Remove the input bridge.

TROUBLESHOOTING & REPAIR

INPUT RECTIFIER REMOVAL AND REPLACEMENT (continued)

F-66

F-66

POWER WAVE 355/405

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

INPUT

RECTIFIER

W

AR

NIN

G

RE

M

OT

E

PO

W

ER

OF

F

ON

STATUS

THERMAL

LINCOLN

ELECTRIC

FIGURE F.30 – INPUT RECTIFIER LOCATION

Advertising