Installation, I / o receptacle specifications, Warning – Lincoln Electric POWER WAVE 355/405 SVM159-A User Manual

Page 20: Control board (dip switch location)

Advertising
background image

INSTALLATION

A-12

A-12

POWER WAVE 355/405

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

I / O RECEPTACLE SPECIFICATIONS

TABLE A.2

WIRE FEEDER RECEPTACLE

PIN

LEAD#

FUNCTION

A

53

Communication Bus L

B

54

Communication Bus H

C

67A

Electrode Voltage Sense

D

52

0vdc

E

51

+40vdc

TABLE A.3

VOLTAGE SENSE RECEPTACLE

PIN

LEAD#

FUNCTION

3

21A

Work Voltage Sense

TABLE A.4

RS232 RECEPTACLE

PIN

LEAD#

FUNCTION

2

253

RS232 Receive

3

254

RS232 Transmit

4

#

Pin5

5

#

Pin4

6

# #

Pin20

20

# #

Pin6

7

251

RS232 Common

DIP SWITCH SETTINGS AND LOCATIONS

DIP switches on the P.C. Boards allow for custom con-
figuration of the Power Wave. To access the DIP
switches:

1. Turn off power to the power source at the dis-

connect switch.

------------------------------------------------------------------------
2. Remove the wrap around cover from the power

source.

3. The control board is on the center assembly facing

the case front. Locate the 8-position DIP switch and
look for switch 8 of the DIP switch.

4. Using a pencil or other small object, slide the switch

to the OFF position if the work sense lead is NOT
connected. Conversely, slide the switch to the ON
position if the work sense lead is present.

5. Replace the wrap around and screws. The PC board

will “read” the switch at power up, and configure the
work voltage sense lead appropriately.

O
N

1

2

3

4

5

6

7

8

WARNING

CONTROL BOARD DIP SWITCH:

switch 1 = reserved for future use
switch 2 = reserved for future use
switch 3 = reserved for future use
switch 4 = reserved for future use
switch 5 = reserved for future use
switch 6 = reserved for future use
switch 7 = reserved for future use
switch 8* = work sense lead

switch 8*

work sense lead

off work sense lead not connected
on work sense lead connected

*Factory setting for Switch 8 is OFF.

CONTROL BOARD (DIP Switch Location)

FIGURE A.7