5. Label and remove the four leads connected to the

reconnect panel. Pliers may be necessary.

6. Label and remove the two leads connected to the

CB2 circuit breaker.

7. Using a crescent wrench, remove the large plastic

nut from around the input power line located at bot-
tom of the rear assembly. See Figure F.35.

8. Locate the steel nut located directly on the other

side of the rear assembly behind the plastic nut
that was previously removed. See Figure F.35.

9. Using a hammer and a flathead screwdriver, firmly

tap the metal nut from the bottom of one of its ribs.
This tapping will loosen the nut. Note: Be sure to
tap from the bottom so the nut loosens in a counter
clockwise fashion if viewed from the front of the
machine.

10. Using a 3/8” nut driver label and remove leads

#202, #203, #206, #207A from the reconnect
switches. See Figure F.35.

TROUBLESHOOTING & REPAIR

CURRENT TRANSDUCER REMOVAL AND REPLACEMENT (continued)

F-75

F-75

POWER WAVE 355/405

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Metal Nut

Plastic Nut

W

ARNING

REMOTE

POWER

OFF

ON

STATUS

THERMAL

LINCOLN

ELECTRIC

#203

#207A

#206

#202

FIGURE F.35 LEAD LOCATIONS