POWER WAVE 355/405

TROUBLESHOOTING & REPAIR

F-48

F-48

PROCEDURE

1. Remove input power to the POWER WAVE

355/405.

2. Using a 5/16” nut driver remove the case wrap-

around cover.

3. Perform the Input Filter Capacitor Discharge

Procedure detailed earlier in this section.

4. Locate the control board behind the front panel of

the machine. See Figure F.17.

5. Using a 5/16” nut driver remove the two screws

from the bottom of the front of the machine. See
Figure F.18.

CONTROL BOARD REMOVAL AND REPLACEMENT (continued)

ST

STATUS

TUS

THERMAL

THERMAL

_

+

Phillips Head
Screws

Phillips Head
Screws

5/16"
Mounting Screws

FIGURE F.17 - CONTROL BOARD LOCATION

FIGURE F.18 CASE FRONT SCREW REMOVAL

W

AR

NIN

G

RE

M

OT

E

PO

W

ER

OF

F

ON

Control Board

STATUS