TROUBLESHOOTING & REPAIR

F-24

F-24

POWER WAVE 355/405

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

POWER BOARD TEST (CONTINUED)

J42

J41

J43

FIGURE F.4 – POWER BOARD TEST

TEST PROCEDURE

1. Remove input power to the Power Wave

355/405.

2. Using the 3/8” nut driver, remove the case

top.

3. Perform

the

Capacitor Discharge

Procedure.

4. Locate the Power Board and plugs J42 and

J43. Do not remove plugs or leads from
the Power Board
. Refer to Figure F.8.

5. Carefully apply input power to the Power

Wave 355/405.

ELECTRIC SHOCK can kill.

High voltage is present when
input power is applied to the
machine.

6. Turn on the Power Wave 355/405. Carefully

test for the correct voltages at the Power
Board according to Table F.4.

7. If either of the 40 VDC voltages is low or not

present at plug J41, perform the DC Bus PC
Board Test
. See the Wiring Diagram.
Also
perform the T1 Auxiliary Transformer
Test.

8. If any of the DC voltages are low or not pre-

sent at plugs J42 and/or 43, the Power
Board may be faulty.

9. Install the case top using the 3/8” nut driver.